Technical Parameters
Technical parameter | Parameter value |
Brand | XUNCHIP |
measurement range | 0~4000uW/cm2 |
measurement accuracy | ± 7% FS |
wavelength range | 240-370nm |
Maximum angle | 90 degrees |
Resolution | 1uW/cm2 |
Interface | RS485/4-20mA/DC0-10V |
Power | DC6~24V 1A |
Power | DC12~24V 1A |
Running temperature | -30~85℃ |
Working humidity | 5%RH~90%RH |
Product Selection
Product DesignRS485,4-20mA,DC0-10VMultiple output methods, the products are divided into the following models depending on the output method.
Product model | output method |
XM8168B | RS485总线 |
XM8168M | 4-20mA |
XM8168V10 | DC0-10V |
Product Size
Why choose this product?
How to use?
Product List
Pictures
Communication Protocol
The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the module or NON-Recorder default baud rate is 9600,8,n,1 ,but data recorder default baud rate is 115200 .
1. Read data (function code 0x03)
Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 01 84 0A .
Address | Function Code | Start Address | Data Length | Check Code |
01 | 03 | 00 00 | 00 01 | 84 0A |
For the correct query frame, the device will respond with data: 01 03 02 00 79 79 A6 , response format:
Address | Function Code | Length | Data 1 | Check Code |
01 | 03 | 02 | 00 79 | 79 A6 |
Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
2. Common data address table
Configuration Address | Register Address | Register Description | Data Type | Value Range |
40001 | 00 00 | 紫外线 | Read Only | 0~65535 |
40101 | 00 64 | Model Code | Read/Write | 0~65535 |
40102 | 00 65 | total number of measuring points | read/write | 1~20 |
40103 | 00 66 | device address | read/write | 1~249 |
40104 | 00 67 | baud rate | read/write | 0~6 |
40105 | 00 68 | communication mode | read/write | 1~4 |
40106 | 00 69 | protocol type | read/write | 1~10 |
For example, the range is 0~200Lux, the analog output is 4~20mA current signal, Illuminance and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is Illuminance range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read Illuminance value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA) | IlluminanceValue (Lux) | Calculation Process |
4 | 0.0 | (200-0)*(4-4)÷(20-4)+0 |
5 | 12.5 | (200-0)*(5-4)÷(20-4)+0 |
6 | 25.0 | (200-0)*(6-4)÷(20-4)+0 |
7 | 37.5 | (200-0)*(7-4)÷(20-4)+0 |
8 | 50.0 | (200-0)*(8-4)÷(20-4)+0 |
9 | 62.5 | (200-0)*(9-4)÷(20-4)+0 |
10 | 75.0 | (200-0)*(10-4)÷(20-4)+0 |
11 | 87.5 | (200-0)*(11-4)÷(20-4)+0 |
12 | 100.0 | (200-0)*(12-4)÷(20-4)+0 |
13 | 112.5 | (200-0)*(13-4)÷(20-4)+0 |
14 | 125.0 | (200-0)*(14-4)÷(20-4)+0 |
15 | 137.5 | (200-0)*(15-4)÷(20-4)+0 |
16 | 150.0 | (200-0)*(16-4)÷(20-4)+0 |
17 | 162.5 | (200-0)*(17-4)÷(20-4)+0 |
18 | 175.0 | (200-0)*(18-4)÷(20-4)+0 |
19 | 187.5 | (200-0)*(19-4)÷(20-4)+0 |
20 | 200.0 | (200-0)*(20-4)÷(20-4)+0 |
As shown in the above formula, when measuring 8mA, current current is 54Lux。
For example, the range is 0~200Lux, the analog output is 0~10V DC0-10Vvoltage signal, Illuminance and DC0-10Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is Illuminance range upper limit, A1 is the lower limit of the range, B2 is DC0-10Vvoltage output range upper limit, B1 is the lower limit, X is the currently read Illuminance value, and C is the calculated DC0-10Vvoltage value. The list of commonly used values is as follows:
DC0-10Vvoltage(V) | IlluminanceValue (Lux) | Calculation Process |
0 | 0.0 | (200-0)*(0-0)÷(10-0)+0 |
1 | 20.0 | (200-0)*(1-0)÷(10-0)+0 |
2 | 40.0 | (200-0)*(2-0)÷(10-0)+0 |
3 | 60.0 | (200-0)*(3-0)÷(10-0)+0 |
4 | 80.0 | (200-0)*(4-0)÷(10-0)+0 |
5 | 100.0 | (200-0)*(5-0)÷(10-0)+0 |
6 | 120.0 | (200-0)*(6-0)÷(10-0)+0 |
7 | 140.0 | (200-0)*(7-0)÷(10-0)+0 |
8 | 160.0 | (200-0)*(8-0)÷(10-0)+0 |
9 | 180.0 | (200-0)*(9-0)÷(10-0)+0 |
10 | 200.0 | (200-0)*(10-0)÷(10-0)+0 |
As shown in the above formula, when measuring 5V, current DC0-10Vvoltage is 100Lux。