 [SM6901B]  temperature, humidity, illuminance, carbon dioxide, smoke, methane, hydrogen sulfide, carbon monoxide eight-in-one hundre

SM6901B

Technical Parameters

Technical parameterParameter value
BrandSONBEST
Temperature measuring range-30℃~80℃
Temperature measuring accuracy±0.5℃ @25℃
Humidity measuring range0~100%RH
Humidity accuracy±3%RH @25℃
Illuminance measuring range0~65535Lux
Illuminance allow deviation±7%
Repeatability test±5%
Illuminance detection chipImport digital
Wavelength range380nm~730nm
CO2 range0~5000ppm
CO2 accuracy±100ppm
Smoke measuring range0~5000ppm
Smoke allow deviation±7%
Smoke Repeatability test±5%
Smoke detection chipImport digital
Temperature characteristics±0.5%/℃
CH4 measuring range0~5000ppm
CH4 allow deviation±7%
CH4 Repeatability test±5%
Temperature characteristics±0.5%/℃
H2S range0~100ppm
H2S accuracy±10ppm
CO range0~100ppm
CO accuracy±10ppm
Communication InterfaceRS485
Default baud rate9600 8 n 1
PowerDC9~24V 1A
DimensionsΦ220mm×150mm

Product Size

SM6901B SM6901B SM6901B SM6901B

Wiring instructions

Why choose this product?

SM6901B SM6901B SM6901B

How to use?

SM6901B

Application solution

SM6901B SM6901B SM6901B

Product List

SM6901B

Pictures

SM6901B

Communication Protocol

    The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the module or NON-Recorder default baud rate is 9600,8,n,1 ,but data recorder default baud rate is 115200 .
1. Read data (function code 0x03)
    Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 08 44 0C .
Address Function Code Start Address Data Length Check Code
010300 0000 0844 0C
    For the correct query frame, the device will respond with data: 01 03 10 00 80 00 00 00 00 00 00 00 00 00 00 00 00 00 00 64 39 , response format:
Address Function Code LengthData 1Data 2Data 3Data 4Data 5Data 6Data 7Data 8Check Code
0103 1000 7900 7A00 7B00 7C00 7D00 7E00 7F00 80 64 39
    Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
2. Common data address table
Configuration Address Register Address Register Description Data Type Value Range
4000100 00temperatureRead Only0~65535
4000200 01humidityRead Only0~65535
4000300 02IlluminanceRead Only0~65535
4000400 03carbon dioxideRead Only0~65535
4000500 04conductivityRead Only0~65535
4000600 05methaneRead Only0~65535
4000700 06conductivityRead Only0~65535
4000800 07carbon monoxideRead Only0~65535
4010100 64Model CodeRead/Write0~65535
4010200 65 total number of measuring points read/write 1~20
4010300 66device addressread/write1~249
4010400 67baud rateread/write0~6
4010500 68communication moderead/write1~4
4010600 69protocol typeread/write1~10

software for test product
After downloading, please read the readme.txt documentation

RV1000 DEGBUG AND TEST SOFTWARE

Data and Software
software for test product
After downloading, please read the readme.txt documentation

RV1000 DEGBUG AND TEST SOFTWARE

Data and Software