--. 0

Product

 [KM21V30-NH3]  0-10V voltage ammonia sensor


KM21V30-NH3 KM21V30-NH3

Technical Parameters

Technical parameterParameter value
BrandKLHA
NH3 range0~100ppm
NH3 accuracy±15ppm
PowerDC12~24V 1A
Running temperature-30~85℃
Working humidity5%RH~90%RH

Product Selection

    Product DesignDC0-5V,DC0-10VMultiple output methods, the products are divided into the following models depending on the output method.
Product model output method
KM21V3V5DC0-5V
KM21V3V10DC0-10V

Product Size

KM21V30-NH3

Why choose this product?

KM21V30-NH3 KM21V30-NH3 KM21V30-NH3

How to use?

KM21V30-NH3

Application solution

KM21V30-NH3 KM21V30-NH3

Pictures

KM21V30-NH3 KM21V30-NH3 KM21V30-NH3 KM21V30-NH3 KM21V30-NH3 KM21V30-NH3 KM21V30-NH3   For example, the range is 0~100ppm, the analog output is 0~5V DC0-5Vvoltage signal, ammonia and DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is ammonia range upper limit, A1 is the lower limit of the range, B2 is DC0-5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read ammonia value, and C is the calculated DC0-5Vvoltage value. The list of commonly used values is as follows:
DC0-5Vvoltage(V)ammoniaValue (ppm) Calculation Process
00.0(100-0)*(0-0)÷(5-0)+0
120.0(100-0)*(1-0)÷(5-0)+0
240.0(100-0)*(2-0)÷(5-0)+0
360.0(100-0)*(3-0)÷(5-0)+0
480.0(100-0)*(4-0)÷(5-0)+0
5100.0(100-0)*(5-0)÷(5-0)+0
    As shown in the above formula, when measuring 2.5V, current DC0-5Vvoltage is 50ppm。
  For example, the range is 0~100ppm, the analog output is 0~10V DC0-10Vvoltage signal, ammonia and DC0-10Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is ammonia range upper limit, A1 is the lower limit of the range, B2 is DC0-10Vvoltage output range upper limit, B1 is the lower limit, X is the currently read ammonia value, and C is the calculated DC0-10Vvoltage value. The list of commonly used values is as follows:
DC0-10Vvoltage(V)ammoniaValue (ppm) Calculation Process
00.0(100-0)*(0-0)÷(10-0)+0
110.0(100-0)*(1-0)÷(10-0)+0
220.0(100-0)*(2-0)÷(10-0)+0
330.0(100-0)*(3-0)÷(10-0)+0
440.0(100-0)*(4-0)÷(10-0)+0
550.0(100-0)*(5-0)÷(10-0)+0
660.0(100-0)*(6-0)÷(10-0)+0
770.0(100-0)*(7-0)÷(10-0)+0
880.0(100-0)*(8-0)÷(10-0)+0
990.0(100-0)*(9-0)÷(10-0)+0
10100.0(100-0)*(10-0)÷(10-0)+0
    As shown in the above formula, when measuring 5V, current DC0-10Vvoltage is 50ppm。
software for test product
After downloading, please read the readme.txt documentation

RV1000 DEGBUG AND TEST SOFTWARE

Data and Software
software for test product
Data and Software
software for test product
After downloading, please read the readme.txt documentation

RV1000 DEGBUG AND TEST SOFTWARE

Data and Software

 Online shop 

 Contact Online 

Email: sale@sonbest.com

TYPE: KM21V30-NH3

WeChat: 13918126020

SKYPE: SOOBUU

Phone: +86-021-66862075

QQ1: 71182854 QQ2:613035997